Btrieve Messages

If any of these messages appear on your screen while operating the HIT City Manager program, the following information will assist with what to do. Error messages appear on the screen when problems occur within the computer or the program. Many are correctable by the operator.

If the message or BT number is not listed here, call HIT Industries 208-642-2334 or 541-823-1000.

SYSTEM ERRORS

These errors are due to the computer. It may have lost its place or something has compromised the integrity of the machine. If you are printing, be sure the printer is turned on and ready. You may try turning it off then back on to see if the error goes away. If it does not, escape out of the program, exit windows, and reset your computer. Then retry whatever it was you were doing.

DO NOT POST AGAIN. CALL HIT INDUSTRIES (208-642-2334) IF YOU WERE IN THE MIDDLE OF POSTING WHEN THIS ERROR OCCURRED!

NO PAPER ERROR WRITING DEVICE PRN - ABORT, RETRY, IGNORE, FAIL?

This error indicates the printer is not ready. Check to be sure the SELECT light is on. When in doubt, turn power off and then back on. This will clear any printer problems. Answer this message with R and retry to print the report. DO NOT ABORT!

PARITY ERROR

If possible, exit what you are doing. Power off the computer, wait a minute or two, turn power back on and try the operation again. If this does not clear the problem, call HIT Industries.

I/O ERROR - BTRIEVE ERROR 02

An error occurred during disk reading or recording. This may indicate that the file has been damaged or that the disk is corrupted.

FILE NOT OPEN - BTRIEVE ERROR 03

An application must perform a successful file open operation before Btrieve can process any other operation. You are trying to access a record in the file and the file is not open.

KEY VALUE NOT FOUND - BTRIEVE ERROR 04

Btrieve could not find the requested item in the specified path. Looking for an account number that doesn't exist

DUPLICATE KEY VALUE - BTRIEVE ERROR 05

An attempt was made to add a record with a key field containing a duplicate key that does not allow duplicate values. Trying to add an item that already exists

FILE NOT FOUND - BTRIEVE ERROR 12

The file name requested does not exist.

DISK FULL - BTRIEVE ERROR 18

This message indicates the disk is full. The file cannot be increased to accommodate more information. Erase any unnecessary files.

FILE MANAGER ERROR - BTRIEVE ERROR 20

The program was entered without loading BTRIEVE. BTRIEVE is a program that allows the GL to work properly. Exit to the system menu and at the C:>\ type BTRIEVE /P:1536 and press enter. Proceed to load the GL.

CREATE I/O ERROR - BTRIEVE ERROR 25

The filename specified could not be created. Possible causes are a full disk directory, a full disk, the disk is write-protected, or the file is already open.

NOT A BTRIEVE FILE - BTRIEVE ERROR 30

The file name specified is not a valid Btrieve data file. Either the file was not created by Btrieve or it was created by an earlier version of Btrieve.

DIRECTORY ERROR - BTRIEVE ERROR 35

An error occurred switching between the current directory and the directory which contains the Btrieve file. Either the current directory or the Btrieve file directory is invalid. Exit to the system menu and at the C:>\ type CD\HIT and press enter. The system echoes back the DOS prompt as C:>HIT\. At this prompt type GLMENU and continue entering data as before.

ACCESS TO FILE DENIED - BTRIEVE ERROR 46

Your application opened a file in read-only mode and attempted to perform an update, delete, or insert. Another possible cause is that the company name was not specified correctly when your application opened the file.

EXPANDED MEMORY ERROR - BTRIEVE ERROR 56

Btrieve will return this message if it receives an error from the expanded memory manager. This usually means that Btrieve was unable to save or restore the memory mapping register indicating an incompatibility with another application that uses expanded memory.

INSUFFICIENT MEMORY FOR PARAMETERS SPECIFIED

One possibility is that your system does not have enough available memory to load Btrieve at the requested size. In that case, remove other memory resident programs or add more memory to your system.

PROGRAM ALREADY LOADED

This means the HIT Software is already running. Check your desktop to find the icon.

If you are running Windows 95 and have not shut down your computer properly, HIT's software left a file in the Windows directory. This file protects the integrity of our program so that it cannot be opened twice. The file MUST be deleted in order to run the HIT Software. To do this - Open EXPLORE and find the Windows directory. Move through the list of files until you locate HIT.SEN. Click one time on the file and press the delete key or drag this file to the recycle bin. Exit Explore and run the Hit software.
We are proud to be an American
Proud to be an American
Hit Industries Inc.,
112 North Main Street, Payette, Idaho 83661
Phone: (208) 642-2334 and (877) 642-2334 / Fax: (208) 642-7153
Email: sales@hitindustries.com
Copyright © 1996 Hit Industries Inc., All rights reserved.